Products 85-96 of 225
Show
Availability: In Stock
Item #: 03-100/32 -
Nylon Resistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-100/32Sefar Part #2: 3A03-0100-098-00 Technical Information Mesh Opening:...
Availability: Out of Stock
Item #: 07-210/35-Medifab -
SEFAR MEDIFAB Quality Passes USP plastics class VI tests Biocompatible according to ISO 10993 Pyrogen-free Non-hemolytic, non-cytotoxic, low extractables Precision monofilament fabrics having defined surface characteristics Customer specific fabrication in a clean room class 7 (ISO 14644-1) Raw materials comply with FDA 21 CFR 177 Raw materials used are polyester (PETP) and polyamide (PA) Non-standard materials, e.g. polyetheretherketone (PEEK) or polypropylene (PP) can be supplied in MEDIFAB...
Availability: Out of Stock
Item #: 07-215/46-Medifab -
SEFAR MEDIFAB Quality Passes USP plastics class VI tests Biocompatible according to ISO 10993 Pyrogen-free Non-hemolytic, non-cytotoxic, low extractables Precision monofilament fabrics having defined surface characteristics Customer specific fabrication in a clean room class 7 (ISO 14644-1) Raw materials comply with FDA 21 CFR 177 Raw materials used are polyester (PETP) and polyamide (PA) Non-standard materials, e.g. polyetheretherketone (PEEK) or polypropylene (PP) can be supplied in MEDIFAB...
Availability: In Stock
Item #: 03-103/39 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-103/39Sefar Part #2: 3A03-0103-102-00Technical InformationMesh Opening:...
Availability: Out of Stock
Item #: 07-224/42-Medifab -
SEFAR MEDIFAB Quality Passes USP plastics class VI tests Biocompatible according to ISO 10993 Pyrogen-free Non-hemolytic, non-cytotoxic, low extractables Precision monofilament fabrics having defined surface characteristics Customer specific fabrication in a clean room class 7 (ISO 14644-1) Raw materials comply with FDA 21 CFR 177 Raw materials used are polyester (PETP) and polyamide (PA) Non-standard materials, e.g. polyetheretherketone (PEEK) or polypropylene (PP) can be supplied in MEDIFAB...
Availability: In Stock
Item #: 03-110/47 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-110/47Sefar Part #2: 3A03-0110-102-00Technical InformationMesh Opening:...
Availability: Out of Stock
Item #: 07-265/47-Medifab -
SEFAR MEDIFAB Quality Passes USP plastics class VI tests Biocompatible according to ISO 10993 Pyrogen-free Non-hemolytic, non-cytotoxic, low extractables Precision monofilament fabrics having defined surface characteristics Customer specific fabrication in a clean room class 7 (ISO 14644-1) Raw materials comply with FDA 21 CFR 177 Raw materials used are polyester (PETP) and polyamide (PA) Non-standard materials, e.g. polyetheretherketone (PEEK) or polypropylene (PP) can be supplied in MEDIFAB...
Availability: Out of Stock
Item #: 03-118/42 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-118/42Sefar Part #2: 3A03-0118-115-00Technical InformationMesh Opening:...
Availability: Out of Stock
Item #: 07-1000/58-Medifab -
SEFAR MEDIFAB Quality Passes USP plastics class VI tests Biocompatible according to ISO 10993 Pyrogen-free Non-hemolytic, non-cytotoxic, low extractables Precision monofilament fabrics having defined surface characteristics Customer specific fabrication in a clean room class 7 (ISO 14644-1) Raw materials comply with FDA 21 CFR 177 Raw materials used are polyester (PETP) and polyamide (PA) Non-standard materials, e.g. polyetheretherketone (PEEK) or polypropylene (PP) can be supplied in MEDIFAB...
Availability: In Stock
Item #: 03-120/34 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-120/34Sefar Part #2: 3A03-0120-122-00Technical InformationMesh Opening:...
Availability: Out of Stock
Item #: 03-120/49 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-120/49Sefar Part #2: 3A03-0120-102-00Technical InformationMesh Opening:...
Availability: In Stock
Item #: 03-125/39 -
NylonResistant to common solvents and to alkalies but are attacked by strong mineral acids.Good abrasion resistance and low coefficient of friction.Working temperature is typically around 239F (115C). Exposure to sunlight can cause discoloration (yellowing).Water absorption is very high.Sterilizing by autoclaving, ETO sterilizing and gamma sterilizing (Under 2.5 Megarads) can be performed. Part Numbers Sefar Part #1: 03-125/39Sefar Part #2: 3A03-0125-102-00Technical InformationMesh Opening:...